Open
Posted
I need a substation gateway configured so it can issue real-time set-points for both voltage and power-factor on a fleet of SMA PV inverters. All messaging must follow the NIE-SSG SCADA technical guidelines and be carried over Modbus (TCP preferred, RTU acceptable if justified). The task is purely about control: the gateway has to accept the grid operator’s Volt/Var and PF commands, translate them into the exact SMA register map, push them to each inverter, and confirm execution with the correct feedback flags. My expectation is a turnkey configuration package that I can load into the existing gateway (Linux-based, supports DNP3 and Modbus out of the box). It should include: • Gateway configuration files or scripts • Register map and scaling document aligned with NIE-SSG requirements • A brief commissioning guide and a remote test session proving dynamic voltage and PF response Only freelancers who can point to hands-on experience doing similar Modbus control of SMA or equivalent inverters should apply—I will be looking at that first.
Project ID: 40471276
52 proposals
Open for bidding
Remote project
Active 2 days ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
52 freelancers are bidding on average £25 GBP/hour for this job

As an Electrical Engineer with a Master's in Embedded Systems and a great deal of practical experience in Modbus control of PV inverters like SMA, I believe I'm the ideal candidate for your Modbus Gateway Voltage & PF Control project. With my strong command over a wide array of microcontrollers, particularly STM32, ESP32, and NXP processors, coupled with my firmware development skills in embedded C/C++, I am adept at translating commands into precise register maps and ensuring seamless execution. My proficiency extends well into not only configuring gateways but also developing efficient hardware and intelligent connectivity solutions to embed them into. In addition, my deep understanding of PCB design and RF hardware gives me an edge when it comes to engineering efficient IoT-ready systems - an advantage that your project requires. On top of that, my experience in designing cloud dashboards and SaaS platforms would be valuable for your remote test sessions and real-time monitoring needs. I understand the importance of aligning with NIE-SSG technical guidelines while working with Modbus communication protocols like TCP and RTU.
£36 GBP in 40 days
8.3
8.3

Hello, I understand you need a Linux-based substation gateway setup that can receive Volt/Var and PF commands from the grid operator, convert them into the correct SMA Modbus register writes, send live set-points to the inverter fleet, and return the right status/feedback flags as per NIE-SSG SCADA rules. I can prepare the gateway config/scripts, SMA register and scaling sheet, and a clear commissioning guide, then support a remote test to prove voltage and PF response. I have worked with Modbus TCP/RTU control, inverter register mapping, Linux gateway setup, and technical documentation for site commissioning, so I can keep this focused on real control behavior, not just monitoring. Which exact SMA inverter models and firmware versions are on site, and do you already have the SMA Modbus register documentation for them? Can you share the NIE-SSG SCADA points list or control/feedback flag requirements you need followed? What is the existing gateway make/model, and does it support custom scripts or only vendor config files? Will the remote test be done against live inverters, a simulator, or a staged test setup? Best regards,
£18 GBP in 31 days
7.1
7.1

With over a decade of experience in Electronics, Embedded Systems, and Microcontroller applications, I am the ideal freelancer for your Modbus Gateway Voltage & PF Control project. My experience includes extensive work with Digital Motor Control, Power Electronics, and Renewable Energy for applications much like yours. I fully understand what it takes to successfully configure and utilize a gateway to issue real-time set-points for voltage and power factor on SMA PV inverters. I have handled similar projects that align with your expectations and boast a track record of producing turnkey results customized to suit unique technical guidelines. This includes generating comprehensive register maps, configuration files/scripts as well as producing brief commissioning guides. My skills extend beyond just delivering on the requirements. I also prioritize the effectiveness and efficiency of my solutions. I offer you not only deep knowledge across various Modbus frameworks but also proficiency in remote testing which is essential for this project. As an added benefit, my familiarity with Linux-based systems sets me up perfectly to provide a solution that aligns seamlessly with your existing setup. I look forward to the opportunity to meet and exceed your needs through my skills and expertise in real time communications and Modbus system optimization.
£25 GBP in 20 days
7.5
7.5

Hi, I can configure the Linux-based substation gateway to translate grid operator Volt/Var and power-factor commands into the correct SMA inverter Modbus register controls. I have experience with Modbus TCP/RTU, inverter control, industrial gateways, Linux-based configuration, register scaling, feedback/status mapping, and commissioning support for energy and automation systems. For this project, I can provide gateway configuration files/scripts, SMA register mapping, scaling documentation aligned with NIE-SSG requirements, and a commissioning guide for testing voltage and PF set-point response. I will focus on reliable real-time control, correct feedback flags, safe command handling, manual test procedures, and clear documentation so the system can be validated with the grid operator requirements. My hourly rate is £20/hour, and I can start by reviewing the SMA inverter model, gateway platform, NIE-SSG control requirements, and existing network architecture. I am available to support a remote test session and help verify dynamic response across the inverter fleet before final handover. Regards.
£20 GBP in 40 days
5.7
5.7

HI, KINDLY READ THROUGH MY PROPOSAL I will deliver a complete, turnkey Modbus TCP configuration for your substation gateway to issue real-time Volt/Var and Power Factor set-points to the SMA PV inverter fleet, fully aligned with NIE-SSG SCADA guidelines. MY APPROACH ✅ Phase 1: Review gateway setup and SMA register map. ✅ Phase 2: Create Modbus TCP mapping, scaling, command translation, execution confirmation, and feedback handling. ✅ Phase 3: Provide configuration files, documentation, commissioning guide, and remote validation session. RELEVANT PROJECTS • Multiple UK substation gateways controlling SMA Sunny Central / Tripower inverters via Modbus TCP for active/reactive power, Volt/Var curves, and PF set-points (including NIE-SSG compliant implementations). DELIVERABLES • Gateway configuration files/scripts (Modbus TCP) • SMA register map & scaling document per NIE-SSG • Commissioning guide & test procedures • Remote test session proving dynamic voltage & PF control QUESTIONS 1. What is the exact gateway platform (Linux-based model)? 2. Which SMA inverter models are in the fleet? 3. Can you share any existing Modbus mapping or register list? Ready to start immediately.
£20 GBP in 40 days
5.8
5.8

Hi, your project aligns closely with my experience in industrial energy-control systems, Modbus gateway integration, and utility-facing inverter automation for grid-support applications. I have 10+ years of experience with SCADA, power-system automation, and inverter communications, including Modbus TCP/RTU integration, dynamic PF/Volt-Var control, and commissioning of distributed energy assets using SMA and equivalent industrial inverter platforms. Approach ✅ I will configure the Linux-based gateway to receive NIE-SSG compliant control commands and reliably translate them into the exact SMA Modbus register structure required for voltage and power-factor control. ✅ I will implement scaling, command validation, execution feedback handling, timeout monitoring, and inverter-state confirmation to ensure stable real-time control across the full inverter fleet. ✅ I will provide structured configuration files, a documented register/scaling map, commissioning procedures, and a supervised remote validation session demonstrating dynamic Volt/Var and PF response behaviour. Questions ✅ Which SMA inverter models and firmware revisions are deployed, and do you already have the corresponding Modbus register documentation available? ✅ Is the gateway already communicating with the inverter fleet over Modbus TCP, or does the transport/network layer still need to be configured? Best, Yaroslav
£27 GBP in 40 days
5.0
5.0

With over [X] years in Industrial Automation, I humbly offer my skills to you for your Modbus Gateway project. My previous work in Wastewater Treatment Plant and Water Treatment Plant Automation required detailed knowledge of SMA PV inverters and Modbus messaging which aligns perfectly with your needs. Specifically, my experience with SIEMENS TIA Portal program and the Simatic Manager program makes me comfortable with your Linux-based gateway system, ensuring I can deliver a turnkey configuration package that aligns with your requirements. At the heart of this project lies control, which I have demonstrated mastery of throughout my career. Be it the PLC expertise with ABB or DELTA, designing of electricity projects with E plan P8 V2.6, or using Honeywell DCS C200 in iron steel industry, control systems are not just what I work on but my passion as well. Lastly, my proven ability to problem-solve and execute complex automation scenarios under pressure makes me a reliable freelancer who meets deadlines even under challenging situations. I offer not just my technical skills but commitment and dedication to ensuring your project is completed to the utmost standards. Choose me and let's power your project to success together!
£27 GBP in 40 days
4.7
4.7

Dear Client, The biggest risk in this project is not sending Modbus commands to SMA inverters. It is ensuring that real-time voltage and power-factor set-points are translated correctly, executed reliably across the inverter fleet, and fully compliant with NIE-SSG SCADA communication requirements under live operating conditions. That is where practical industrial control and inverter integration experience matters. I would approach this by: 1. reviewing the NIE-SSG technical requirements, SMA inverter register maps, and existing gateway capabilities to identify communication constraints, scaling requirements, command timing, and feedback validation needs 2. configuring the Modbus control architecture, including real-time set-point translation, inverter addressing, status verification, scaling logic, and fault handling for stable field operation 3. preparing a turnkey deployment package including gateway configuration files, register mapping documentation, commissioning procedures, and remote validation/testing support One key question: Do you already have the SMA inverter models and NIE-SSG mapping documents available, or should those be verified during the initial phase? Message me and I’ll help build a reliable gateway control solution that operates cleanly in real-world SCADA environments and supports stable dynamic inverter control. Best regards, Prat PCB Must Innovations
£25 GBP in 40 days
6.3
6.3

Hi, I am Zakaria. As a Master’s graduate in Automatics and Systems, power system automation and communication protocols form the core of my background. I specialize in configuring substation gateways and mapping real-time control sequences between grid SCADA and inverter fleets. Why I am the best fit for your SMA fleet control integration: * SMA Modbus Experience: Expert in SMA Modbus register mapping for reactive power control, navigating direct Power Factor (PF) targets and active Volt/Var (Q(V)) curves. * Protocol Translation: Skilled in configuring Linux gateways to map upstream SCADA commands into precise SMA 16/32-bit registers with exact scaling factors. * NIE-SSG Compliance: Deeply familiar with NIE-SSG guidelines, incorporating strict heartbeat handshakes and reading back Grid Guard status flags for feedback verification. * Proven Success: Multiple industrial automation and protocol integration projects completed on this platform with 5-star ratings and 100% client satisfaction. I am ready to deliver the turnkey configuration package, register maps, and remote commissioning support. Are your inverters equipped with Modbus TCP cards directly, or are they networked via an intermediate Data Manager M / Cluster Controller?
£27 GBP in 40 days
4.4
4.4

❤️❤️❤️❤️❤️ Hi, I will configure the gateway to translate grid operator Volt/Var and PF set-points into the exact SMA register map and ensure correct execution feedback , likely causes for failure are mismatched scaling (register decimal position) and timing/ack flag mapping between NIE-SSG and SMA firmware. I will implement a Modbus(TCP)-first workflow: map NIE-SSG commands to SMA registers with scaling tables, push set-points, and verify execution via inverter feedback flags and watchdog retries in a lightweight Linux daemon. I previously delivered a Modbus/TCP gateway for a 2MW PV site translating DNP3 signals to SMA inverters with verified dynamic Volt/Var response, and commissioned remote tests for an off-grid microgrid controller. I can also add automated regression tests for set-point timing. Would you like me to target Modbus TCP initially or prepare RTU fallback? Do you prefer Modbus TCP as primary and RTU only as fallback, and can I get sample NIE-SSG command traces from your operator? Best regards, Bohdan
£18 GBP in 40 days
3.1
3.1

Hi, I am a full-stack developer with 8 years of rich experience in software development, with a background in Linux gateways, Modbus TCP/RTU, SCADA integrations, embedded systems, inverter control, automation, register mapping, signal processing, and technical documentation. I can configure your substation gateway to translate grid operator Volt/Var and power-factor setpoints into the correct SMA inverter Modbus register writes, handle scaling and feedback flags, prepare the NIE-SSG-aligned register map, and support remote commissioning to verify real-time voltage and PF response. I'm an individual freelancer and can work on any time zone you want. Please contact me with the best time for you to have a quick chat. Looking forward to discussing more details. Thanks. Emile.
£25 GBP in 40 days
3.3
3.3

I’ve read your Modbus gateway brief, and this is straightforward for me. I’ve delivered over a dozen similar projects where a voltage regulator needs to be monitored and controlled via Modbus RTU, and I can have a working prototype ready quickly. I handle the full cycle—firmware, a custom PCB if needed, and a simple interface to set voltage levels. The budget of 20 works for a focused scope, and I’ll keep the deliverables tight: a reliable gateway that reads voltage and allows you to adjust it from a serial terminal or a lightweight dashboard. I’ve shipped similar systems for clients in the UK before, so I understand the expectations around reliability and documentation. If you’re ready to move forward, send me the exact model of your voltage regulator and the control protocol details. I’ll get you a functional solution without any fluff.
£20 GBP in 40 days
3.3
3.3

Real-time setpoint delivery for both voltage and power factor on a Modbus gateway is timing-sensitive work. I would configure the polling cycle and register map to keep latency tight, and set up the Linux service to restart cleanly on any comms fault so the substation never loses control authority. I can start today and have this configured and tested within 3 days. The bid reflects the description as written and may adjust once we walk through the full scope. Want to jump on a quick call?
£36 GBP in 7 days
3.0
3.0

Hello, I’m Cora May, thanks for the clear Modbus Gateway Voltage & PF Control brief. I’ve configured substation-style gateways to translate Volt/Var and power-factor commands into vendor-specific inverter register maps, with real-time set-point write/feedback validation and standards-aligned messaging. For your Linux gateway (DNP3 + Modbus supported), I’ll provide a turnkey configuration package: scripts/config files, an NIE-SSG-aligned register map with scaling/units, and the control translation layer for SMA PV inverters over Modbus TCP (RTU only if it’s technically required). I’ll also include a concise commissioning guide and a remote test procedure that proves dynamic voltage and PF response, including the correct execution/feedback flags and failure-handling so the SCADA side stays deterministic. How many distinct inverter models/firmware variants are in the fleet, and do you already have the NIE-SSG point list (or should we create it from the gateway’s addressing plan)? Also, are the Volt/Var and PF commands provided as absolute set-points or percent-of-range values from the grid operator?
£18 GBP in 29 days
2.8
2.8

I understand that you're particularly interested in finding a freelancer with hands-on experience in Modbus control of SMA or equivalent inverters to tackle your substation gateway configuration project. Although my expertise lies mainly within writing, my journey has taken me across a range of experiences and disciplines, one such being automation and Linux. With this technical knowledge, I can confidently contribute smart and intuitive solutions to your project. Specifically, I'm confident in my ability to configure your existing gateway precisely to follow the NIE-SSG SCADA technical guidelines you've mentioned while ensuring real-time set-points for voltage and power-factor on your SMA PV inverters crave. What sets me apart is an unwavering dedication towards learning new skills and applying them in practical settings and scenarios. By recruiting me for this project, you'll not just be getting someone who can configure the gateway to align with Modbus (both TCP and RTU options) standards, but someone capable of providing a comprehensive package that meets your precise requirements—a turnkey configuration package inclusive of gateway configuration files/scripts, register map with scaling aligned impeccably to NIE-SSG's needs alongside a brief commissioning guide and remote test session validating dynamic voltage and power factor response.
£18 GBP in 40 days
1.6
1.6

Hello, I can configure a Linux-based substation gateway for real-time voltage and power-factor set-point control over Modbus TCP, aligned with NIE-SSG SCADA requirements and the SMA inverter register map. I have hands-on experience with Linux gateways, Modbus-based control, automation systems, register mapping, scaling, feedback validation, and technical commissioning documentation. For this task, I’ll focus on safe and traceable control logic: receive Volt/Var and PF commands, translate them into the correct SMA registers, write set-points to each inverter, then confirm execution through feedback/status flags. I’ll prepare the gateway configuration files or scripts, a clear register and scaling document, and a commissioning guide covering network setup, test procedure, rollback steps, and validation checks. I can also support a remote test session to prove dynamic voltage and PF response against the grid operator commands. I am ready to start once the gateway model, SMA inverter model, current register documentation, and NIE-SSG guideline version are available. Best, Smit
£27 GBP in 40 days
1.8
1.8

SMA Modbus register maps are something i've worked around on embedded energy monitoring builds, and the Linux gateway side (config files, scripting, Docker-wrapped services) is familiar ground. That said, direct NIE-SSG SCADA commissioning and live SMA inverter fleet control isn't something i've done at utility scale, so i want to be straight with you there before you read further. If the gap matters, send me the gateway model and the NIE-SSG doc and i'll tell you quickly whether the config work is within reach or not.
£27.90 GBP in 7 days
0.2
0.2

⭕ Hello, Client ⭕ Drawing from my extensive experience in e-commerce automation and custom ERP integration, I offer a unique skill set that aligns seamlessly with your project requirements. I am a seasoned expert in utilizing and configuring various platforms like Modbus (TCP), SMA PV inverters, Linux-based systems, and DNP3 - skills that you are specifically looking for. In addition, I bring to the table extensible experience in working with large datasets and integrating diverse systems smoothly. This translates into a business-like approach to any task, including your need for a turnkey configuration package, commissioning guide, and remote test session. Promptness and accuracy are my tools of trade; I am here to provide a consistent and reliable voltage & power-factor control solution for your substation gateway. Furthermore, customer satisfaction is my top priority. This means not only delivering high-quality work but also offering post-project support. After completion, you can count on me to be readily available for any concerns or issues that may arise. You can expect competitive pricing without compromising on the quality of work - this perfect balance makes me the best fit for your project. In conclusion, hiring me ensures not only solid expertise in Modbus control of SMA inverters but also a customer-centric approach aimed at making your vision a reality. So let's get started on streamlining your business operations by enhancing efficiency and productivity!
£18 GBP in 32 days
0.0
0.0

Hello Sir, As an experienced Full Stack and DevOps Engineer, I am uniquely suited to handle your modbus control project. Over the last 9+ years, I've honed my skills in backend architecture and Linux systems management - crucial elements of your project. I'll leverage this experience to deliver a robust and efficient solution for your substation gateway. One of my core strengths is my familiarity with a wide range of programming languages including Node.js, Python, Ruby on Rails, and PHP. This means I can comfortably work with Modbus and adhere to the NIE-SSG SCADA technical guidelines. Additionally, my expertise in cloud technologies like AWS, GCP, and Azure will ensure that your project not only meets your current needs but also scales seamlessly in the future. Over the years, I've developed a systems mindset - always prioritizing maintainability, performance, and long-term growth. In line with this approach, I will provide you with a comprehensive turnkey configuration package containing all necessary files and documents aligned with NIE-SSG's requirements. Furthermore, I'm experienced in providing detailed remote test sessions to confirm proper functionality. If you're looking for someone who can take full ownership of your project from design to deployment; someone who brings not just talent but tenacity to every task; then I'm the ideal fit for your team. Let's leverage my skills and expertise to build a reliable and high-perfo Thanks! John
£37 GBP in 16 days
0.0
0.0

Hi There, I can configure your Linux-based gateway to translate grid operator Volt/Var and PF commands into the SMA register map, pushing real-time set-points over Modbus TCP with NIE-SSG-compliant messaging and verification feedback. I’ve hands-on experience with Modbus control of SMA inverters, embedded Linux gateways, and delivering turnkey automation packages, including register maps, scaling docs, and commissioning guides for field testing. For your project, I will deliver gateway config files or scripts, a clean register map aligned to NIE-SSG, a concise commissioning guide, and a remote test plan to prove dynamic voltage and PF responses, all packaged for quick load and operation. Could you share the exact gateway model, current SMA register map, and NIE-SSG documentation you want me to strictly adhere to for the kick-off? Best regards, Chibike
£37 GBP in 21 days
0.0
0.0

Newry, United Kingdom
Payment method verified
Member since Jan 26, 2024
£250-750 GBP
£250-750 GBP
£750-1500 GBP
£20-250 GBP
£10-15 GBP / hour
$1500-3000 USD
$30-250 USD
$250-750 USD
₹12500-37500 INR
€250-750 EUR
€250-750 EUR
$3000-5000 AUD
$15-25 USD / hour
$10-30 USD
$250-750 USD
$25-50 USD / hour
$1500-3000 USD
₹1500-12500 INR
£10-15 GBP / hour
₹1500-12500 INR
£20-250 GBP
$30-250 NZD
$30-250 USD
$10-30 USD
£18-36 GBP / hour