Closed
Posted
Paid on delivery
I need a simple, reliable way to power-up twenty-five individual 12 V DC regulators from a single point. My plan is to use a standard mechanical wall switch: flip it once and every regulator comes alive together. Key points to cover • The switch must be a regular wall-mounted mechanical type—no timers, dimming, Wi-Fi, or other smart features. • Include an LED indicator that lights whenever the regulators receive power so I have a clear visual confirmation. • Everything runs on 12 V DC; please choose components rated with comfortable headroom for current and voltage. What I’m expecting from you 1. A clear wiring schematic showing how the 25 regulators, the wall switch, the LED indicator, and any required relays or distribution blocks are interconnected. 2. A concise parts list with part numbers and ratings so I can order everything quickly. 3. Brief installation notes—anything special I should watch out for when mounting the switch, protecting the LED, or distributing current evenly. If you can design a neat, safe solution that keeps parts count low and assembly straightforward, let’s get started.
Project ID: 40659800
54 proposals
Remote project
Active 3 days ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
54 freelancers are bidding on average $436 USD for this job

Drawing on my expertise as an Electrical Engineer with extensive experience in circuit design and electronics, I can offer you a solution that satisfies all your requirements. With regard to the mechanical wall switch aspect, I assure you that my skills are not limited to smart features or timers. I am adept at designing and implementing practical, reliable systems, which includes integrating simple components such as regular wall-mounted switches. For your project, I will provide a detailed wiring schematic illustrating how the 25 regulators, wall switch, LED indicator, and any required relays or distribution blocks will be interconnected. Additionally, I'll supply a concise parts list including part numbers and ratings so you can quickly order everything needed. Furthermore, a crucial aspect of this project is ensuring proper distribution of current along with protective measures for the LED and guaranteed safety. My background in Industrial Automation equips me with the ability to handle these concerns efficiently. Finally, my strength in PCB design means I can plan and implement a system that optimizes current flow while keeping assembly simplistic. Let's get started on your reliable power switch solution!
$750 USD in 7 days
8.5
8.5

Hi, I am an embedded systems engineer with over 16 years of experience designing reliable power-control and distribution systems for consumer and industrial products. I can produce a clean 12 V solution in which the standard wall switch controls a suitably rated DC relay or contactor, avoiding the need to carry the full regulator load through the switch. The design will include a protected LED indicator, fused distribution for all 25 regulator branches, appropriate wire and terminal ratings, and sensible voltage/current headroom. I will provide a clear labeled schematic, an order-ready BOM with manufacturer part numbers and ratings, and concise installation notes covering grounding, fusing, wire sizing, mounting, and even current distribution. What is the maximum input current of each regulator, including startup surge, and what is the rating of the 12 V supply? This determines the relay, fuse, wiring, and distribution-block sizes. I can also support revisions if the installation constraints require adjustments. Please message me to discuss the details and get started.
$500 USD in 4 days
7.6
7.6

Hi, I have experience in designing Circuits and can complete your project. I have expertise in the following: 1- Designing schematic and PCBA 2- Ordering the PCBA and getting boards manufactured. 3- Writing firmware for the PCBA to make sure everything works as expected. 4- I can also develop smartphone apps to communicate and control the hardware. If you wish we can discuss in chat. Thank you.
$400 USD in 7 days
7.4
7.4

Hi there, I have carefully reviewed your 12 V distribution requirements and can design a simple, reliable solution to power all 25 regulators simultaneously from one standard mechanical wall switch. With nearly five years of experience in mechatronics, electrical design, DC power distribution, protection circuits, relays, and wiring systems, I can prepare a clean schematic using appropriately rated switching, fusing/distribution, and an LED power-status indicator. Depending on the total current, I can also use the wall switch only as a control input for a properly rated relay/contactor to improve reliability. I will provide the wiring schematic, complete parts list with ratings/part numbers, and concise installation notes. Please send me a message with the regulator current requirements so I can size the switching and distribution components correctly. Best regards, Samuel tshibangu
$500 USD in 1 day
6.5
6.5

I can design a simple, robust 12V DC power distribution system to control all 25 regulators from a single mechanical switch. System Design & Deliverables: - Power Architecture: Low-current mechanical wall switch controlling a heavy-duty 12V automotive/industrial relay to safely drive the full load without arc pitting. - Distribution: Fused power distribution blocks for equal voltage drop across all 25 channels. - Schematic & BOM: Clean schematic diagram with an LED indicator circuit, complete BOM (exact MPNs with amperage/voltage headroom), and clear wiring notes. Ready to start immediately and deliver a safe, production-ready package!
$300 USD in 7 days
6.6
6.6

HI, KINDLY READ THROUGH MY PROPOSAL I will design a simple, reliable solution so one standard mechanical wall switch turns on all 25 × 12 V DC regulators together, with a clear LED power indicator. MY APPROACH ✅ Use a suitably rated 12 V DC relay (or contactor) controlled by the wall switch ✅ Distribute power to the 25 regulators through a clean distribution block or bus ✅ Add an LED indicator that lights whenever the regulators are powered DELIVERABLES - Clear wiring schematic - Concise parts list with ratings and part numbers - Brief installation notes QUESTIONS 1. What is the maximum current draw of each regulator (or the total expected load)? 2. Is the wall switch already 12 V DC compatible, or will it switch the relay coil only? I am Ready to start immediately.
$250 USD in 3 days
6.5
6.5

With my vast experience and skills in Circuit Design, Electrical Engineering, and Electronics, I am utterly confident in my ability to deliver a reliable solution for your project. My proficiency in using SolidWorks and AutoCAD will enable me to provide an efficient wiring schematic, indicating the clear interconnection of the 25 regulators, wall switch, LED indicator, as well as any other required components. Not only will I meet your requirements for a regular wall-mounted mechanical switch with an LED indicator, but I'll also go an extra mile to ensure the components selected have comfortable headroom for both current and voltage - guaranteeing their durability while providing the necessary functionality. This back up on comfortable headroom is crucial to avoid potential issues like voltage drop or overloading of a circuit. Given my valued skills in Troubleshooting and Mechanical Design, I'll also provide additional installation notes highlighting specific things you should watch out for during mounting such as protecting the LED and distributing current evenly. My goal is to make this solution not just functional but flawless in every way possible. Let's get started and transform your vision into reality!
$266 USD in 1 day
5.6
5.6

⭐⭐⭐⭐⭐ I can design this as a simple, reliable 12 V distribution system where one standard mechanical wall switch powers all 25 regulator branches and the LED provides an immediate power-on indication. I’d keep the design straightforward: a suitably rated DC switching element, fused/distributed 12 V supply, individually protected regulator branches where appropriate, and a dedicated current-limited LED indicator. The goal will be low part count without compromising conductor, switch, fuse and connector ratings. I’ll provide: • Clear wiring schematic showing the switch, distribution, LED and all 25 regulators • Concise BOM with part numbers, voltage/current ratings and suitable headroom • Installation notes covering polarity, fusing, wire sizing, terminal selection and LED protection • A practical distribution arrangement to keep voltage drop and current concentration under control The one specification I’d confirm first is the maximum input current of each 12 V regulator, including any startup/inrush current. With 25 units, that determines the total supply current and whether the wall switch can safely switch the load directly or should operate a DC-rated relay/contactor. Once I have that figure, I can size the switch, protection and distribution hardware correctly rather than guessing.
$500 USD in 7 days
5.6
5.6

Hello, I am Muhammad Javed, an Electrical Engineer with more than 10 years of experience in DC power distribution, control circuits, wiring schematics, and low-voltage electrical systems. I have thoroughly understood your requirement for controlling 25 individual 12 V DC regulators from a single standard mechanical wall switch. I can design a simple, reliable distribution and switching circuit where one switch powers all regulators simultaneously while maintaining appropriate current capacity, protection, and clean wiring. I will prepare a clear wiring schematic showing the 12 V DC source, wall switch, LED power indicator, distribution/fuse arrangement, and all 25 regulator connections. Based on the actual regulator input current, I will correctly size the switch/relay, conductors, protection devices, and distribution points with suitable voltage and current headroom. I will also provide a concise BOM with practical component part numbers, voltage/current ratings, and specifications so everything can be sourced easily. Installation notes will cover polarity, LED protection, fuse protection, wire sizing, current distribution, terminal connections, and safe mounting practices. The design will prioritize low component count, straightforward assembly, reliable operation, and easy maintenance. I am available to start immediately and can deliver the schematic and parts documentation promptly.
$500 USD in 7 days
6.2
6.2

Hi, I’m a Senior Electronics Engineer with 10+ years of experience in power distribution, DC/DC systems, and custom PCB design. I have designed multiple 12V/24V power solutions including protected power rails, relay switching circuits, and high-current distribution systems for industrial and embedded applications. Approach ✅ I will design a 12V power distribution architecture using a mechanical wall switch, properly rated relay/MOSFET switching stage, fuse protection, and a distribution block feeding all 25 regulators. ✅ I will select components with adequate voltage/current margins, including the LED indicator circuit, connectors, protection devices, and thermal considerations. ✅ I will prepare a clear wiring schematic, BOM with manufacturer part numbers, and concise installation guidelines for safe assembly and reliable operation. Questions ✅ What is the input current requirement of each 12V regulator, and what is the expected total system current? ✅ Are the 25 regulators identical models, and do they need individual fusing or only a main protection fuse? ✅ Is the 12V source a battery system or a regulated AC/DC power supply? Best, Yaroslav
$500 USD in 7 days
5.3
5.3

Hello I can design a simple, reliable 12 VDC power-distribution system that switches all 25 regulators from one standard mechanical wall switch. With 15+ years of experience in embedded electronics, industrial control, power electronics, and PCB design, I can provide a clean schematic, appropriate component ratings, and practical installation guidance. My proposed approach will include: * A standard mechanical wall switch controlling the 12 V distribution. * Properly rated relay/MOSFET switching if required by the total load current. * A protected LED power indicator that illuminates whenever the regulators are energized. * A suitable distribution block/fused distribution arrangement for the 25 individual regulators. * Correct wire sizing, current capacity, voltage-drop considerations, and protection. * Components selected with comfortable voltage/current headroom for reliable long-term operation. I will deliver a clear, easy-to-follow wiring schematic, concise BOM with manufacturer part numbers and ratings, and brief installation notes covering switch mounting, LED protection, fusing, grounding, and balanced power distribution. I can also review the total current of the 25 regulators and determine whether a single relay, multiple branches, or a MOSFET-based solution is the most reliable and cost-effective option. I focus on practical, production-ready designs with low parts count and straightforward assembly. Best Regards Hamza
$250 USD in 5 days
5.4
5.4

As an experienced electrical engineer with ample skills and knowledge in circuit design, mechanical design, and project management, I am confident I can deliver the excellent solution you need for your wall switch setup. Despite having substantial expertise in CAD software, my ability to simplify complex designs is something that sets me apart from the others. In this case, I will craft a clear and concise wiring schematic detailing interconnections between the 25 regulators, your desired standard mechanical wall switch, the LED indicator, and necessary relays or distribution blocks. Considering your requirement of simplicity and reliability devoid of Wi-Fi or other smart features, rest assured that I'll deliver exactly what you need - a hassle-free solution that powers up all regulators simultaneously with a simple flick of the switch. Additionally, I'll ensure adequate headroom for voltage and current in component selection, minimizing the risk of any electric mishaps. On top of that, I'll incorporate a brightly lit LED indicator as per your preference to give you instant visual confirmation of power reception by all the regulators.
$258 USD in 3 days
5.0
5.0

As a seasoned professional with an extensive background in circuit design and electronics, I strongly believe I'm the right fit for your project. Drawing from my experience of designing numerous electrical systems, I understand how important simplicity, reliability, and safety are for any project to succeed. With your need for a standard wall-mounted mechanical switch and an LED indicator to ensure proper functioning, I can create a clear wiring schematic that interconnects all the necessary components - the 25 regulators, the wall switch, the LED indicator, and any required relays or distribution blocks. My concise parts list will include catalogued part numbers and ideal ratings to make ordering quick and effortless for you.
$254 USD in 1 day
5.0
5.0

Hi, I can design a clean, low-parts-count solution for this: Switching: Mechanical wall switch triggers a 12V relay (30–40A) rather than switching full load current directly — protects the switch and scales safely. Distribution: Relay output feeds a fused terminal block; each regulator gets its own branch fuse so one fault doesn't affect the others. LED indicator: Wired on the switched output side through a resistor, so it only lights when regulators actually have power. Protection: Main fuse + per-branch fuses + relay flyback diode. Deliverables: Wiring schematic, parts list with part numbers/ratings, and installation notes (wire gauge, fuse sizing, mounting tips). To finalize part numbers I just need your total current draw per regulator and preferred connector type. Can turn around the schematic + parts list in 2–3 days, with one revision round included.
$500 USD in 6 days
4.7
4.7

✅✅✅✅✅ I can design this as a simple, robust 12V distribution system with the mechanical wall switch doing only the control work and a properly rated relay handling the combined regulator load. For 25 individual regulators, I’d focus on keeping the wiring clean while providing adequate protection and current headroom. The design would include: Main 12V input fuse/protection Mechanical wall switch + suitably DC-rated relay/contactor Fused distribution block feeding all 25 regulators 12V LED indicator across the switched output Clear wiring/schematic showing grounding, polarity and protection Parts list with practical, orderable part numbers and ratings I’ll size the relay, fuse, distribution hardware and wire gauge based on the actual combined current rather than guessing, with appropriate margin for continuous operation and startup conditions. I’ll also provide concise installation notes covering DC switch ratings, fuse placement, LED protection, terminal sizing and sensible current distribution. The one specification I’d need before final component selection is the input current (or wattage) of each 12V regulator, including whether that rating is continuous or peak. With that, I can produce the complete schematic and BOM around the real load.
$500 USD in 7 days
4.4
4.4

As a multipurpose professional with a successful history in engineering, design and project management, I am well-equipped to tackle your request for an efficient wall switch for 25 regulators. I am a seasoned electrical engineer with profound knowledge in electronics and the relevant software; this enables me to ensure precise calculations and strategic planning to meet your specific needs. What sets me apart is my ability to think holistically while keeping things simple. My proficiency in drafting clear wiring schematics will enable you to easily comprehend and execute the wiring connections for your project. I also understand the significance of maintaining comfortable headroom for current and voltage and will incorporate components that best align with your specific power requirements.
$255 USD in 1 day
4.2
4.2

With a decade of experience in electrical engineering and a passion for clean, practical solutions, I am confident that I can provide you with the perfect design for your wall switch project. My expertise in firmware development, PCB design, and embedded product development, paired with extensive knowledge of microcontroller platforms and experience with similar projects will make this project an easy stride. To ensure a sturdy and reliable system, I will apply my skills in designing circuits, power-systems, and sensor interfaces to create a blueprint for you that maintains a comfortable headroom for both current and voltage concerns. Ultimately what distinguishes me as a stellar candidate is an understanding that great engineering goes beyond just getting things to work - it involves clean documentation and open communication with clients. I can guarantee your satisfaction through my focus on practical engineering, reliability in both firmware and hardware design , responsive communication and impeccable documentation practices. Hiring me means not only getting a functional product but also having an ear that listens throughout the project process- let's make this project work from inception to production.
$550 USD in 8 days
3.9
3.9

Hello, The key part of this project is **safely switching twenty-five 12 V DC regulators from one wall-mounted mechanical switch while keeping the wiring simple and the power path clearly indicated**. I can help you handle this accurately and efficiently without overcomplicating the process. I have hands-on experience with **Electronics, Electrical Engineering, and Circuit Design**, including compact power-distribution layouts and relay-based switching logic. For your project, I would focus on **the schematic for the 25-load switching path**, **the LED power-on indicator with proper protection**, and **a practical parts list with ratings that leave comfortable headroom**, while making sure the final result is **safe, reliable, and easy to assemble**. I can start immediately and expect to complete this within 7 days. One detail I'd like to confirm before starting: **should the regulators be switched together through a single relay, or would you prefer a grouped distribution layout to reduce inrush current and wiring stress**? Best regards, Miguel
$250 USD in 7 days
4.0
4.0

Okay, I got what you want exactly. I am a PCB Designer and Embedded Engineer with 10 years of experience, providing power distribution design, DC power management, control electronics, schematic development, BOM creation, and reliable hardware solutions. In my opinion, the best solution is to use a simple master DC power distribution architecture where the mechanical wall switch controls a properly rated relay or contactor, allowing all 25 regulators to receive power from a single controlled source. I will keep the design clean and reliable with proper current handling, protection, and an LED status indicator for quick visual confirmation. This project is very similar to my previous works. ✅ So, I will divide your project into three major steps. 1️⃣ Circuit design: Create the complete wiring schematic showing the wall switch, relay control, LED indicator, protection components, and 25 regulator connections. 2️⃣ Component selection: Prepare a concise BOM with recommended part numbers, current ratings, voltage ratings, connectors, and suitable protection devices. 3️⃣ Documentation and review: Provide installation notes covering wiring layout, current distribution, LED protection, mounting considerations, and final design recommendations. Via private chatting or meeting, I will provide the creative idea and good tech solution for your project. Best regards. Maksym
$500 USD in 7 days
3.4
3.4

Hi, Thank you for sharing your project—I understand you need a straightforward, reliable solution to power up 25 individual 12V DC regulators using a standard mechanical wall switch, complete with a clear LED indicator for status confirmation. Your focus on simplicity, reliability, and ease of installation is spot on, and I’m confident I can deliver exactly what you’re looking for. Based on your requirements, my approach is to design a robust wiring schematic that utilizes a suitably rated mechanical wall switch to control a relay (or contactor if needed for higher current), distributing power evenly to all 25 regulators. The LED indicator will be wired to illuminate only when the regulators are powered, ensuring you always have an immediate visual check. All components will be selected with appropriate voltage and current margins for long-term reliability and safety. I have extensive hands-on experience designing and implementing low-voltage power distribution systems for industrial and laboratory environments—most recently, I designed a similar centralized control panel for a client managing multiple 12V devices in a test facility. That project required careful current management and straightforward maintenance, which aligns perfectly with your goals here. With my background in electrical engineering and practical project management, I can ensure your solution is safe, efficient, and easy to assemble. I’m ready to start designing immediately and am confident you’ll be pleased with the results. - Detailed wiring schematic including all components and interconnections - Comprehensive parts list with specific part numbers and ratings - Concise installation notes with best practices for mounting and safety - Ongoing support for any troubleshooting or follow-up questions I believe I am an excellent fit for your project and can get started right away. Best Regards, James
$250 USD in 2 days
0.0
0.0

Hamburg, United States
Member since Aug 20, 2026
₹12500-37500 INR
$250-750 CAD
₹600-1500 INR
₹600-1500 INR
₹750-1250 INR / hour
₹1500-12500 INR
£20-250 GBP
₹12500-37500 INR
$30-250 USD
₹600-1500 INR
$250-750 USD
₹75000-150000 INR
$55-300 USD
$30-250 AUD
$10-30 USD
₹1500-12500 INR
₹600-1500 INR
₹1500-12500 INR
₹1500-12500 INR
₹600-1500 INR