
Completed
Posted
Paid on delivery
I have a detailed PDF site plan that already marks the exact mast positions for a small public forecourt in front of a commercial store. The poles are fixed at either 4 m or 5 m height; their locations and mounting heights must prefereably stay untouched. What I need is a complete lighting calculation, performed in Dialux (or Relux if you prefer), that proves the design meets current Danish norms and regulations. You will receive: • the PDF plan and PDF formats • technical data sheets for the selected luminaires and masts Your task is to import the plan, assign the specified fittings to the predefined poles, and iterate aiming for compliant average and minimum horizontal illuminance, uniformity, and glare values in line with Danish public-area requirements. Once satisfied, deliver: • the native Dialux/Relux project file • a calculation report (PDF) highlighting point-by-point values, isolines, U₀, Umin/avg, and glare indices • a concise summary page I can forward to local authorities Keep fixture orientation, mast height, and position exactly as drawn; only photometric parameters or lamp counts may change if necessary to achieve compliance.
Project ID: 40453836
14 proposals
Remote project
Active 4 days ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs

I am a lighting designer with hands-on experience in DIALux EVO lighting simulations and compliance-based lighting design for commercial, residential, and industrial projects. I can develop a complete lighting calculation package that aligns with Danish lighting standards and European norms, including EN 12464 requirements for illuminance, glare control, uniformity, and energy efficiency. My work includes detailed lux calculations, fixture layouts, daylight analysis where required, and optimized lighting solutions that balance compliance, aesthetics, and energy performance. For your project, I will prepare accurate DIALux simulations using the provided architectural drawings and project specifications. The deliverables can include lighting layouts, calculation reports, luminaire schedules, false-color renderings, and compliance documentation suitable for submission and client review. I am comfortable coordinating with architects, MEP consultants, and contractors to ensure the lighting design integrates properly with the overall building design while meeting Danish regulations and sustainability expectations.
$250 USD in 3 days
0.0
0.0
14 freelancers are bidding on average $440 USD for this job

Hi, This is Maksim. I understand you need a complete lighting calculation and compliance study for a small public forecourt using the exact mast positions and mounting heights already defined in your PDF site plan, while ensuring the final solution complies with current Danish lighting regulations and public-area standards. The project requires importing the provided plans into Dialux or Relux, assigning the specified luminaires to the fixed 4 m and 5 m poles, and optimizing the photometric setup without altering mast locations or heights unless fixture configuration adjustments are required for compliance. I have 10 years of experience in technical lighting coordination, CAD-based planning, and engineering support for exterior commercial and public-space projects, including detailed lighting analysis and standards-oriented documentation. I can provide the complete native Dialux or Relux project files, full calculation reports with isolines and point-by-point analysis, U₀ and glare calculations, as well as a concise compliance summary prepared for submission to local authorities. I understand the importance of maintaining the fixed site geometry while achieving code-compliant performance through fixture aiming, photometric adjustments, and optimized luminaire configuration. I would be happy to review the PDF plans and luminaire data sheets and begin the lighting simulation process immediately. Best Regards
$500 USD in 7 days
5.6
5.6

Hi, I'm an electrical and lighting designer with experience in DIALux and I'm ready to start developing your project. I've viewed the attached files. I'll provide you with the native DIALux files and photometric reports with the correct lux levels. I guarantee maximum availability and collaboration. Contact me. See you soon!
$400 USD in 7 days
5.1
5.1

Dear Hiring Manager, Greetings. I am a professional Lighting engineer and a Dialux EVO expert. I have read your job description and want to let you know that I can give you a solution by performing lighting calculations on Dialux EVO. Please have a look at my portfolio for my previous project experiences. You are requested to consider me for this project. I assure you that you will get quality work according to your requirements. If you have any question, you can discuss with me any time. Many Thanks. Kind Regards, Haris.
$350 USD in 3 days
5.1
5.1

I help architects, MEP engineers, and project managers deliver lighting designs that are compliant, energy-efficient, and built to last — on time and within spec. What I do: → Photometric calculations (DIALux Evo, AGi32, RELUX, Dialux 4.13) → Lighting design for offices, warehouses, sports fields, roads & residential → Compliance with EN 12464-1, IESNA, EN 13201, AS/NZS 1158 → Full documentation ready for construction and permits. Why clients come back: Most of my work comes from repeat clients and referrals. In 15 years I've learned that good lighting design isn't just about lux levels — it's about understanding the space, the budget, and the deadline.
$500 USD in 5 days
4.9
4.9

Are you looking for a lighting engineer to validate your forecourt layout against Danish compliance standards without altering the approved mast locations? I can support this using DIALux evo or Relux, working directly from your supplied PDF plan and luminaire photometric files. Since mast positions and 4–5 m heights are fixed, I’ll focus on optimizing fixture aiming, optics, tilt, and lamp configuration while preserving the exact site arrangement. Scope I Can Support Import the site layout, place all luminaires on predefined poles, run full outdoor lighting simulation, and verify average/minimum horizontal illuminance, uniformity (U₀), and glare according to relevant Danish Standards / EN roadway-public area standards applicable to commercial forecourts. Deliverables Native project file (.evo/.rdf) Full calculation PDF report with lux grid, isolines, glare results, point-by-point values Compliance summary sheet for authority submission Recommendations if fixture wattage/optics adjustments are required while keeping pole placement unchanged I have experience in technical simulation, engineering layouts, and standards-based design reviews, and can provide a clear submission-ready package. Best regards, Hasan A.
$260 USD in 5 days
3.7
3.7

Hello, With over two decades of experience in the field, wielding proficiency in architectural and electrical engineering, I am well-prepared to take on your Dialux lighting simulation project. Specifically, my architectural design background and deep familiarity with Danish norms and regulations assure you an understanding of the unique constraints and lighting standards required for public areas here. Such foresight helps me better anticipate challenges, make informed decisions and deliver results that align with local authorities’ expectations. I also bring critical expertise in AutoCAD, a skill that I can employ efficiently when working with your detailed PDF plan. Delivering to you not just the final native Dialux/Relux project file but also a robust calculation report will shed light on every intricate detail in terms of point-by-point values, isolines, U₀, Umin/avg, and glare indices. I’ve completed similar projects for [residential/commercial/public] developments and can ensure precise, timely, and cost-effective results. My portfolio: https://www.freelancer.com/u/MHS1490?frm=MHS1490&sb=t Please feel free to share your project details, and I’ll provide a customized proposal and timeline. Looking forward to collaborating with you! Best regards Mohammad
$300 USD in 7 days
3.1
3.1

Hi, I’m a Senior Lighting Designer with 5+ years of international experience in public-space and exterior lighting projects. I can complete the full DIALux calculation package while keeping the exact mast positions and heights as provided. The NORLYS KOSTER PRO 1821 pole-mounted fixture suits the character of the space well, and I can optimize its distribution, orientation, and photometric performance to achieve both compliance and a comfortable public-space atmosphere. Deliverables: • Native DIALux/Relux file • Full calculation report with lux plots, uniformity & glare values • Authority-ready summary page Turnaround: 3-4 working days.
$250 USD in 4 days
2.8
2.8

Hello, I'm LIGHTING DESIGNER with 10+ years of experience. My experience in lighting design includes lighting projects for: Residential and Commercial Buildings Lighting • Landscape Lighting • Industrial Lighting • Sport Terrains Lighting • Street Lighting • Parking Lots Lighting • Facade Lighting • Emergency Lighting I am able to offer: 1. Lighting concept 2. Choosing fixtures for realization of lighting concept or working with certain fixtures. 3. Lighting calculations (Dialux Evo, Dialux 4.13, Relux) with output report. 4. Work with photometry ( IES, LDT) 5. Work with drawings in Autocad 6. 2D visualizations of lighting (Photoshop) 7. 3D visualizations of lighting (Lumion Pro, 3ds Max) Feel free to contact me and have a nice day!
$250 USD in 3 days
0.0
0.0

Hello sir As a Senior Electrical Power Systems & MEP Design Engineer leading a multidisciplinary freelance engineering team, I specialize in high-precision infrastructure design, complex system modeling, and zero-error project execution. I will lead the complete engineering and technical development of your project, transforming your raw design concepts and site layouts into fully verified, permit-ready packages tailored for seamless execution. Engineering Goal & Impressive Solution High-Fidelity Multi-Discipline Synchronization for Zero-Conflict Infrastructure. The principal challenge in fast-track project delivery is eliminating design drift and spatial service collisions between heavy infrastructure mains, distribution lines, and architectural boundaries. For a comprehensive view of our capabilities, please explore our portfolio for work samples and client testimonials. Regards, Eslam
$500 USD in 3 days
0.0
0.0

Skurup, Sweden
Payment method verified
Member since Jun 2, 2016
$30-250 USD
$30-250 USD
$30-250 USD
$250-750 USD
$30-250 USD
$30-250 USD
$30-250 USD
₹12500-37500 INR
$10-30 USD
$30-250 CAD
$10000-20000 USD
$750-1500 USD
$15-25 USD / hour
$150 USD
$30-250 USD
₹750-1250 INR / hour
$250-750 USD
$15 USD
$250-750 USD
$250-750 USD
$30-250 USD
$750-1500 USD
$10-11 USD
£20-250 GBP
$10-30 CAD