In Progress
Posted
Paid on delivery
I am fitting-out a new 600 m² commercial gym and need a certified electrical engineer to turn my concept layout into a complete, code-compliant design package. The scope centres on two areas: • Lighting – I have a current layout design to use and need to include, gym, rooms and fight gym, reception and back-of-house, plus fully detailed emergency lighting coverage with photometric calculations. • Power distribution – A standard commercial board is fine; no specialised high-load machinery is planned. The design should simply balance normal gym equipment, HVAC connection points and general socket circuits while providing room for future expansion. Please prepare drawings and schedules in AutoCAD or Revit (whichever you prefer) and use Dialux/Relux or similar for lighting calculations. All work must align with local electrical codes and any relevant IEC/AS/NFPA sections. Deliverables I need from you: • Single-line diagrams and load calculations • Lighting layout with lux plots and emergency overlay • Circuit schedules and panel board schedules • Cable sizing, containment routing and breaker selection • A brief design report summarising assumptions and compliance references I will provide the architectural plan in DWG as soon as we start. Let me know your estimated turnaround and any information you still need.
Project ID: 40701978
12 proposals
Remote project
Active 4 days ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
12 freelancers are bidding on average $494 AUD for this job

Hello, I can develop the complete electrical design package for your 600 m² commercial gym, using the provided DWG concept layout as the foundation. I will coordinate the gym areas, fight gym, rooms, reception, back-of-house spaces, HVAC connection points, equipment loads, and future expansion allowances. The package will include lighting and emergency lighting layouts, Dialux/Relux-based lux and photometric calculations, single-line diagrams, load and voltage-drop calculations, panel and circuit schedules, cable and containment selections, and breaker coordination. I will prepare the drawings in AutoCAD or Revit and document the applicable local code and IEC/AS/NFPA compliance assumptions in a concise design report. I will also review circuit balance, emergency coverage, access and maintenance considerations, and practical routing before finalising the deliverables. Could you please confirm the project location, incoming supply details, governing code, and whether the design must be submitted for authority approval? I can begin by reviewing the architectural DWG and confirming the governing electrical code, supply characteristics, preferred luminaire specifications, and any authority submission requirements. Kind regards, Muhammad Awais
$750 AUD in 13 days
5.4
5.4

Hello I can develop your 600 m² commercial gym concept into a coordinated electrical design package, covering lighting, emergency lighting, power distribution, and detailed calculations. Scope of Work: ☑️ Lighting layouts with Dialux/Relux lux and emergency-lighting calculations ☑️ Single-line diagram, load calculations, panel/circuit schedules ☑️ Cable sizing, containment routing, breaker selection, and socket circuits ☑️ Coordinate gym equipment, HVAC connections, reception, rooms, fight gym, and back-of-house ☑️ Design report with assumptions and applicable IEC/AS/NFPA/local-code references ☑️ AutoCAD or Revit deliverables with clear, construction-ready documentation Estimated turnaround is 5–7 business days after receiving the DWG and project/code information. Where a local certified electrical engineer's professional seal is legally required, final review and certification should be completed by the appropriately licensed professional. Best Regards, Mohand
$500 AUD in 5 days
4.2
4.2

Hello, I reviewed the requirements, and the core challenge is coordinating the 600 m² gym’s lighting and power distribution into one compliant electrical design while accounting for emergency coverage, equipment loads, HVAC connections, and future expansion. I would develop the AutoCAD or Revit drawings, single-line diagram, load calculations, lighting and emergency layouts with Dialux/Relux results, circuit and panel schedules, cable and breaker selections, containment routing, and a concise compliance report. I have worked on similar commercial electrical design, lighting calculations, power distribution, emergency lighting, and MEP documentation projects and can share relevant examples once we connect in chat. Best Regards, Muskan
$250 AUD in 1 day
3.0
3.0

Hi, As a Master’s graduate in Automatics and Systems, power electronics enthusiast, and hardware control engineer, I bring strong technical precision and extensive experience designing industrial/commercial electrical systems, power distribution, and automated control layouts to deliver code-compliant engineering packages. Key Strengths & Technical Approach: 1. Power Distribution & Single-Line Diagrams: Proficient in load calculations, circuit balancing, cable sizing, containment routing, and breaker selection (IEC/NFPA compliant). I will design a clean single-line diagram (SLD) and panel board schedule for your 600 m² facility with built-in headroom for future expansion. 2. Lighting Design & Dialux Photometrics: Experienced in using Dialux to perform detailed photometric calculations, lux plots, and uniform lighting distributions across dedicated zone, paired with an emergency lighting overlay meeting local code standards. 3. Complete CAD/Revit Deliverables: I will deliver a full engineering package in AutoCAD/Revit including single-line diagrams, circuit schedules, cable sizing tables, lighting/power layouts, and a brief technical design report detailing compliance references and system assumptions. Once you share the DWG architectural plan, I can confirm the exact turnaround time (typically 5–7 business days). I am available to start immediately upon receiving the architectural files. Let's connect to review your concept layout! Best regards, Zakaria L.
$755 AUD in 7 days
2.8
2.8

I have 5+ years of experience in electrical/MEP design, including commercial power distribution, lighting layouts, load calculations and detailed electrical documentation. For your 600 m² commercial gym, I can develop the complete electrical design package covering: Lighting layouts for gym, rooms, fight gym, reception and back-of-house Emergency lighting layout with required coverage and photometric calculations Single-line diagrams and load calculations Panel/DB schedules and circuit schedules Cable sizing, breaker selection and containment routing Power distribution for gym equipment, HVAC points and general sockets Spare capacity/future expansion provisions AutoCAD/Revit drawings DIALux/Relux lighting calculations with lux plots Design report with assumptions and applicable code/compliance references I can work with the provided DWG architectural plan and coordinate the electrical layouts accordingly. Please share the project location/jurisdiction, applicable local electrical code, architectural DWG, utility supply details (voltage/phase/frequency), and any existing lighting fixture specifications. Note: Where statutory certification, signing/sealing or approval by a locally licensed electrical engineer is required, the final package can be submitted for review and certification by the appropriately licensed professional.
$300 AUD in 4 days
1.7
1.7

The main technical risk is accurately balancing the detailed lighting requirements for diverse gym zones, including the fight gym and emergency lighting, with the power distribution needs. I handle this by first creating precise Dialux photometric models for every area, ensuring code compliance and desired lux levels, then integrating those results into a coherent Revit model for power and lighting layouts. I will deliver complete AutoCAD or Revit drawings with detailed schedules. This includes full photometric calculations for all gym spaces, reception, and back-of-house areas, also incorporating emergency lighting coverage. Power distribution will be clearly mapped out, accounting for HVAC, standard circuits, and room for future expansion. What is the desired level of detail for the emergency lighting coverage, specifically regarding fixture placement density? I need your concept layout drawing to begin. My 5.0 rating across 10 reviews here, and Preferred Freelancer status, matters because it shows consistent delivery on technical electrical engineering projects.
$390 AUD in 21 days
0.0
0.0

I can develop a complete, code-compliant electrical design package for your 600 m² commercial gym, covering both lighting and power distribution. I will work from your architectural DWG and coordinate the electrical design with the gym areas, fight gym, rooms, reception, back-of-house and HVAC requirements. Deliverables: Electrical single-line diagrams and load calculations Complete lighting and emergency lighting layouts DIALux/Relux lux calculations and emergency coverage Circuit and panel schedules Cable sizing, containment routing and breaker selection Future expansion provisions Brief design report with design assumptions and applicable code references AutoCAD/Revit drawings and editable source files I will prioritize proper circuit balancing, practical routing, equipment coordination and clear documentation suitable for construction. I can target approximately 7–10 days after receiving the complete architectural plan and project requirements. Why Choose Me: Strong electrical design and CAD experience Practical approach to commercial power and lighting systems Detailed, coordinated and construction-ready documentation Clear communication and revisions during design development
$250 AUD in 5 days
0.0
0.0

Hello, I’ve carefully reviewed your project requirements, and I believe my architectural experience and 3D visualization skills make me a strong fit for this project. I’m an experienced architect specializing in architectural design, 3D modeling, and high-quality rendering. I work confidently with AutoCAD, SketchUp, and Revit, and I have previously worked on projects with similar requirements. What I can offer you is not just drawings, but a clear and accurate architectural solution that matches your requirements, with close attention to dimensions, details, materials, and overall design quality. I understand that communication and reliability are just as important as technical skills. I’ll keep you updated throughout the project, listen carefully to your feedback, and make sure the final result reflects exactly what you have in mind. If you’re looking for an architect who takes the project seriously, pays attention to details, and delivers professional work on time, I’d be happy to help. Feel free to message me and let’s discuss your project and how I can bring your idea to life. Best regards
$250 AUD in 7 days
0.0
0.0

Gold Coast, Australia
Payment method verified
Member since Sep 10, 2026
$250-750 AUD
₹1500-12500 INR
₹600-1500 INR
$250-750 USD
$250-750 USD
$750-1500 USD
$30-250 USD
$30-250 USD
$10000-20000 CAD
$250-750 USD
$30-250 USD
$250-750 USD
₹12500-37500 INR
₹600-1500 INR
₹7500-8500 INR
$250-750 USD
₹1500-12500 INR
$250-750 AUD
$250-750 USD
$10-30 USD
$750-1500 USD