Its the project about voltage and power factor control of a Isolated system using MATLAB.
In this project we have utilized semiconductor devices to make an efficient control of 3-phase
voltage. Our objective is to make a close loop controller which can track the desired voltage
level (Specified by the user or the Appliance rating) from the fixed supply voltage with
significantly less distortion level. We have made a Simulation of this model in MATLAB
SIMULINK by taking some standard values of filter parameters. We have used a two stage
power electronic converter here among which in the first stage it is a 3-phase uncontrolled
rectifier and the later stage is a 3-phase inverter. Between these two converters a link is there
known as D.C link, which is used for obtaining ripple free dc at the input side of the inverter.
The AC/DC converter i.e Rectifier is fed from Grid which is generally a 3-Phase supply and a
filter (Containing inductor and capacitors) is used along with it to reduce the ripple of the
voltage at the output of the rectifier. The DC/AC converter i.e Inverter uses a close loop
mechanism to maintaining the reference value. The purpose of the comparator is to make an
comparision between the actual value and the reference value and make an error between them
if it’s [url removed, login to view] logic decision is made by the Proportional and Integral controller
or P.I controller, reference [3] which controlled the output voltage of the inverter and make it
as desired [url removed, login to view] long as we have discussed about the necessity of the voltage controller but in a actual power
system we should concern about the Power Factor also. Before going into further details lets
make a quick review of Power factor terminology and its imporatnce in Power Systems.
In our project we have implemented a predicted power factor controller using static capacitor
along with an automated controllable A.C voltage controller whose output voltage is varying
according to our desired power factor and it makes improved the sending end power factor
irrespective of the load torque demand, thus by relieving the industry from the penalty of
lowering the power facto r.
ID dự án: #12906472
Về dự án
11 freelancer chào giá trung bình₹22676 cho công việc này
Hi! My name is Fernando Téllez. I am a senior year student of electrical engineering at Universidad Simón Bolívar (USB), one of the most prestigious universities in my country (Ranked 34° at the QS University Rankings: Thêm
Hi, I am a post graduate power electronics engineer and having very good experience in product design and development. I am excellent in SMPS, supplies design from few watts to KW range using Buck, Boost, Buck -boost, Thêm
I have high proficiency in Matlab including SPSS Statistics, Mathematics, Machine learning and Statistics analysis. Once you share the project, I will have a look & confirm if I can do it. I’m honest, creative and a Thêm
Hello, I have read and understood your project requirements. I have very good skills and experience in matlab and will therefore make a success of your work looking forward to working with you. Regards, Ad Thêm
I am a faculty of Mathematics with having a prior knowledge in MATLAB and previously I helped out few of my colleagues in MATLAB programming to their own work. So I can guarantee you that You will be not disappointed i Thêm
I have worked in a very similar problem, but I have used a Controlled rectifier to convert the AC to DC and a Inverter to convert DC to AC. The rectifier and the Inverter both uses Space Vector Pulse Width Modulation. Thêm
As I am a power electronics engg. and I am working on MATLAB/SIMULINK based projects since 3 years. After looking at your project details, it seems to be an academic or related work, if so then I can also help in writi Thêm